Lucene search

K

E-alert Firmware Security Vulnerabilities

cve
cve

CVE-2022-0922

The software does not perform any authentication for critical system...

6.5CVSS

6.7AI Score

0.0005EPSS

2022-04-01 11:15 PM
56
cve
cve

CVE-2018-8854

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not properly restrict the size or amount of resources requested or influenced by an actor, which can be used to consume more resources than...

7.5CVSS

7.3AI Score

0.003EPSS

2018-09-26 07:29 PM
21
cve
cve

CVE-2018-8856

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software contains hard-coded cryptographic key, which it uses for encryption of internal...

9.8CVSS

9.3AI Score

0.003EPSS

2018-09-26 07:29 PM
21
cve
cve

CVE-2018-8852

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. When authenticating a user or otherwise establishing a new user session, the software gives an attacker the opportunity to steal authenticated sessions without invalidating any existing session...

8.8CVSS

8.3AI Score

0.003EPSS

2018-09-26 07:29 PM
20
cve
cve

CVE-2018-8850

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not validate input properly, allowing an attacker to craft the input in a form that is not expected by the rest of the application. This would lead to parts of the unit receiving unintended input, which may result....

9.8CVSS

9.4AI Score

0.01EPSS

2018-09-26 07:29 PM
21
cve
cve

CVE-2018-8844

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The web application does not, or cannot, sufficiently verify whether a well-formed, valid, consistent request was intentionally provided by the user who submitted the...

8.8CVSS

8.5AI Score

0.002EPSS

2018-09-26 07:29 PM
18
cve
cve

CVE-2018-8846

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software does not neutralize or incorrectly neutralizes user-controllable input before it is placed in output that is used as a web page that is then served to other...

6.1CVSS

5.8AI Score

0.001EPSS

2018-09-26 07:29 PM
22
cve
cve

CVE-2018-8848

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software, upon installation, sets incorrect permissions for an object that exposes it to an unintended...

7.5CVSS

7.4AI Score

0.002EPSS

2018-09-26 07:29 PM
21
cve
cve

CVE-2018-14803

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The Philips e-Alert contains a banner disclosure vulnerability that could allow attackers to obtain extraneous product information, such as OS and software components, via the HTTP response header that is normally not available to.....

5.3CVSS

4.8AI Score

0.001EPSS

2018-09-26 07:29 PM
23
cve
cve

CVE-2018-8842

Philips e-Alert Unit (non-medical device), Version R2.1 and prior. The software transmits sensitive or security-critical data in cleartext in a communication channel that can be sniffed by unauthorized actors. The Philips e-Alert communication channel is not encrypted which could therefore lead to....

8.8CVSS

8.1AI Score

0.001EPSS

2018-09-26 07:29 PM
22